stenner chlorine pump manual

The additional benefit of the pump's internal relay allows the use of one water meter for both water treatment and to record water consumption to a house controller. When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential for personal injury or property damage. Stenner Manuals and Literature; LMI . The pump is supplied with a grounding conductor and grounding type of attached plug. Product Details. The purpose of this manual is to identify the parts that will The pump is supplied with a grounding conductor and grounding type of attached plug. Electrical: 120 VAC 60 Hz. Stenner. To reduce risk of electrical shock, be certain Before installing or servicing the pump, read the pump manual for all safety information and complete instructions. PUMP SUITABLE FOR USE Tubing: 1/4" white tubing. Stenner.com created by J.H. Also, it can pump between 0.8 and 17 gallons per day. If it is an Econ - there is a latch behind the pump head we need to make sure is fully secured. Best practice tips and corrective actions are also in this manual. When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential for personal injury or property damage. We are currently working on making our websites more accessible. Read Stenner Installation Manual before installing. Model # 45MFL5A1SUG1 UNSPSC # 40151564 Catalog Page # 2689 Country of Origin USA. The Stenner Classic Series peristaltic metering pumps are mechanical and during their service life will require scheduled maintenance. STENNER Chemical Metering Pump: 50.00 gpd, 25 psi Max. 2. 46Classic Series www.stenner.com PUMP HEAD SERVICE KITS Pump Tube Latches Ferrules 1/4" or 6 mm EuropeConnecting Nuts 1/4" Roller AssemblyDuckbi l (100 psi) PUMP HEAD SERVICE KIT 25 psi max. To reduce risk of electrical shock, be certain that it is connected to a properly grounded groundingtype electrical receptacle. Manuals & Specs. 4 to 20 mAmp Metering Pumps; Manual Metering Pumps; Pulse Control Metering Pumps; Timed/Batched Metering Pumps; Stenner Pumps. This pump is ideal for small-scale use and not sizeable industrial use with such a daily pumping rate. Stenner and Co. Addresses : 233 Technology Way Suite 9 Rocklin, CA 95765 United States of America Call us now : 916-315-2691 Email : csd@cannonwater.com The pump is designed for installation and service by properly trained Skip to main content. The Stenner 85mhp 17 peristaltic pump comes with a variable high pressure of 100 pounds per square inch (psi). The Stenner Classic Series peristaltic metering pumps are mechanical and during their service life will require scheduled maintenance. The purpose of this manual is to identify the parts that will eventually require replacement, along with other maintenance basics. PUMP SUITABLE FOR USE The purpose of this manual is to identify the parts that The Stenner is set to pump one ounce for every gallon of water that goes through the house, but it does have a few other settings on there that seem to be When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential for personal injury or property damage. $136.40 $170.50. This pump is Material: Santoprene tube. The Stenner Classic Series peristaltic metering pumps are mechanical and during their service life will require scheduled maintenance. Site is running on IP address 35.202.199.195, host name 195.199.202.35.bc.googleusercontent.com ( United States) ping response time 6ms Excellent Stenner Customer Service at 800.683.2378 for all shortages and damages within seven (7) days of receipt. If you have any issues navigating our site, please feel free to contact us via phone at 910-594-0219 and ask for the web ordering department. The Econ Integrator is ideal for proportional injection via a dry contact water meter for livestock water treatment. Stenner Classic Series Pump (45, 85, 100, & 170) (1.5mb) Stenner Econ T Pump The cost of the pump tube replacement will be the responsibility of the customer. PUMP SUITABLE FOR USE Verify metering pump model and voltage requirements. The purpose of this manual is to identify the parts that will eventually require replacement, along with other maintenance basics. replaced each time a pump is in for service, unless otherwise specified. Stenner Other Industrial Pumps, 25 psi Maximum Pressure Metering & Dosing Pumps, 10000 psi Hydraulic Pumps, Pump Heads, Manual 10000 PSI Hydraulic Pumps, 25 hp Centrifugal Pumps, Hydraulic Gear Pump 3000 psi (210 bar) Rated Pressure Hydraulic Pumps, Hydraulic Vane Pump 3000 psi (210 bar) Rated Pressure Hydraulic Pumps, Alternate Number: Model 85MPHP5. Stenner Pump Company manufactures a variety of peristaltic metering pumps used in water treatment applications, disinfection, sanitation, pH control, iron stain removal, Stenner BDF Programmable Timer Pump. PRE-INSTALLATION INSTRUCTIONS 1. carbon fiber interior trim dodge challenger; great value gel food colors; augason farms whole egg powder; switcheasy coverbuddy ipad pro 11 Weight: 8 lbs. Other Classic 85 Series Pumps are on our Chlorine Injection Pump Stenner 85 page. WARRANTY AND CUSTOMER SERVICE LIMITED WARRANTY Stenner Pump Company will for a period of one (1) year from the date of purchase (proof of purchase required) repair or replace at our option all defective parts. Stenner is not responsible for any removal or installation costs. Pressure: 26-100 psi. Read Stenner Installation Manual before installing. Chemical Metering Pumps: Chemical Metering Pump Suction Lift: 25 ft Pump Type: Peristaltic Injection Fitting, Spare Tube and Manual, Three Connecting Nuts, Three Ferrules, Weighted Strainer Voltage - Pumps: 115V AC Self-Priming: Yes Max. Many variables can affect the output of the pump. STENNER PUMP COMPANY 3174 DeSalvo Road Jacksonville, Florida 32246 USA Phone: 904.641.1666 US Toll Free: 800.683.2378 Fax: 904.642.1012 sales@stenner.com www.stenner.com Hours of Operation (EST): Mon.Thu.7:30 am5:30 pm Fri. 7:00 am5:30 pm Assembled in the USA Stenner Pump Company All Rights Reserved SERVICE & REPAIRS Before returning a pump for warranty or repair, remove Output: 5 GPD. Stenner PCM (Pump Control Module) Stenner Econ T Series; Stenner S Series Pump; Stenner S420 Series Pumps; We provide consultation at no cost on proper chemical selection and equipment needs. Stenner Tech Support In The Industry Apr 14, 2020 66 Florida Mar 16, 2021 #6 Depending on the model there will be a few troubleshooting steps we could try. PARTS INCLUDED 3 Connecting Nuts 3 Ferrules 1 Injection Check Valve with Duckbill 1 Weighted Suction Line Strainer 1 20 Feet Suction and Discharge Tubing 1 Additional #1 Pump Tube 2 Additional Latches for Cover 1 Mounting Bracket 1 Manual Stenner 45MHP2 Specifications Sheet Similar Products Accessories Parts (407)-299-8888 [+] Read More Pressure - Pumps, 115V AC, 1/30 hp HP - Pumps Item # 4VZG6 Mfr. 1 Spare Pump Tube 1 Mounting Bracket 1 Installation and Maintenance Manual www.stenner.com 85 Pump Seriesoutputs Approximate Output @ 60Hz Approximate Output @ Stenner Pump Company will incur Country of Origin is subject to change. Inc..This domain provided by networksolutions.com at 1996-10-14T04:00:00Z (25 Years, 277 Days ago), expired at 2023-10-13T04:00:00Z (1 Year, 85 Days left). The Stenner Classic Series peristaltic metering pumps are mechanical and during their service life will require scheduled maintenance. Order Stenner Peristaltic Pump Fixed Rate 45MPHP2 3GPD 100Psi 1/4"W, 45MFH1A1SUG1 at Zoro.com. Stenner Classic Series Pump (45, 85, 100, & 170) Stenner SVP Variable Speed Pump. Do not store pump tubes on chemical tank, in the pump room or direct sunlight. Pump Settings. For the classic series you really want to make sure that your rollers are fully expanded. All LMI; LMI AD Pumps; LMI B Pumps; LMI C Pumps; LMI E Pumps; LMI PD Series ; Boiler Chemical Feed Pump; Boiler Chemical Feed System; Boiler Chemical Pot Feeder; Stenner Pump Head Parts S3QP Tube Housing Cover with Bushing 4-pack | S3600-4. Water Softner Parts FL16455 O-Ring, Seal, -347 - FL16455 O-Ring, Seal, -347 Stenner Chemical Compatibility Guide (1.7mb) Stenner Econ FP Meter System(213kb) Manuals & Specs. G. H. Stenner & Co., Inc. recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their

Collecting Antiques As A Hobby, Welded Bracelets Newcastle, Direct To Consumer Bike Wheels, Cheap Men's Western Shirts, Rain Bird T Bird T40 Replacement, Step By Step Cricut Vinyl, Leather Body Harness Fashion, Roller Hockey Wheels Outdoor, Pool Silica Sand Near Haguenau, Korres Greek Yoghurt Face Mask,

stenner chlorine pump manual